Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Center roller lever.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models . )
Sealing characteristics that meet IEC IP67 degree of protection FLV-EP50W.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material
FLV-EP50W
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables FLV-EP50W.
Multiple mounting possible with Switches with Plungers .
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Output: DPDT.
Lighting: LED (with built-in reduced-voltage lighting function).
Operating voltage: 200/220 VAC/VDC FLV-EP50W.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2 .
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Unit type: CJ1 Basic I/O Units.
Product name: DC Input/Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 16 inputs, 16 outputs;
Input voltage,Input current,
Maximum switching capacity, 224VDC, 7mA,
12 to 24 VDC, 0 FLV-EP50W.5 A;
Commons, 16 points, 1 common;
External connection, MIL connector.
No. of words allocated: 2 words.
Current consumption: 5V, 0.13A; 24V, --.
Standards: UC1, N, CE.
A Wide Range of Basic Mixed,
I/O Units for Different Applicationss,
and Wiring Methods FLV-EP50W.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems.
FLV-EP50W Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=FLV-EP50W&select=5