Contact type: Standard load (250 VAC, 2 A; 125 VDC 0.4 A).
Operation: Momentary operation (Self-resetting).
Output: DPDT.
Lighting: Incandescent lamp, 28 VDC.
Operation Unit color symbol: Enter the desired color symbol for the,
Pushbutton in @@. R (Red); Y (Yellow); G (Green); A (Blue); W (White) .
Pushbutton Switch Series with.
Square 40-mm Body FLV-TCC1.
Combines miniature design with distinct but soft sense of operation
FLV-TCC1
Easy panel mounting from the front and simple lamp replacement.
without tools. Output: SPDT.
Lighting: LED without Voltage Reduction Unit.
Operating voltage: 5 VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white FLV-TCC1.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Specifications: Outputs, PNP (+ common), 4 points FLV-TCC1.
I/O connections: Sensor I/O connector .
Rated internal circuit power supply voltage:
Supplied from the communications. connector.
Rated I/O power supply voltage: 24 VDC.
Remote I/O Terminals with High.
Degree of Environmental Resistance.
(IP67) in Product Lineup Including.
Economical Input, Output, and Mixed I/O Models.
Common Smart Slave functionality provides strong support for equipment,
operation status monitoring and effective maintenance.
High degree of environmental resistance with dust-proof and drip-proof,
construction. (IP67)
MModels with one connector foor two outputs are available to make easier,
connection with hydraulic valve devices FLV-TCC1.
(Models with 16 outputs and models with 16 mixed I/O)Terminal: Screw terminal (-B).
Actuator: Hinge lever.
High-capacity Switch Capable of,
Handling 20 A Loaadss with Large FLV-TCC1.
Inrush Currents.
Same shape as OMRON Z Basic Switches except in pin,
plunger position, yet endures inrush currents as large as 75 A.