Type: 1-conduit.
Mounting direction: Front-side mounting.
Conduit size: M20.
2NC (Slow-action).
The Special Operation Key Activates a Direct.
Opening Mechanism to Open the Contacts.
and Shut Off Control Circuits when Protective.
Doors Are Opened on Machine Tools or Other.
Equipment.
Conforms to EN (TÜV) standards corresponding to the CE marking FQ-CR15050F-M.
Certified by UL and CSA standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened
FQ-CR15050F-M The EN-certified.
direct opening mechanism is indicated by on the Switch.
Malfunctions and false operation prevented by special Operation Key.
Wide temperature range specifications: −40 to 80°C FQ-CR15050F-M.
Degree of protection of the switch box: IP67 (EN60947-5-1). Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Applicable load: 15 A, 200 to 480 VAC.
Compact, Slim-profile SSRs with Heat,
Sinks. Models with No Zero Cross for,
a Wide Range of Applications FQ-CR15050F-M.
RoHS compliant .
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output currents. (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification). Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see tthe state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV FQ-CR15050F-M.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation FQ-CR15050F-M.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
FQ-CR15050F-M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=FQ-CR15050F-M&select=5