Sensing distance: 5 to 100 mm.
Smart Static Electricity Sensing: Making Static Electricity Visible.
Compact sensor head and smart digital amplifier measure,
the electrostatic charge quantity of workpieces at all times.
Multi-point measurements and data logging of the static,
electricity quantity can be performed easily .
Best long-distance, high-precision measurements in the industry G2R-14 AC110. Safety outputs *3: Instantaneous, 2(Semiconductor);
OFF-delayed*2, 2 (Semiconductor)
G2R-14 AC110
Auxiliary outputs *4: 2(Semiconductor).
Logical AND connection: Inputs, 2(Semiconductor); Outputs, 2(Semiconductor).
No. of input channels: 1 or 2 channels.
Max. OFF-delay time *1: 15 s G2R-14 AC110.
Rated voltage: 24 VDC.
Terminal block type: Screw terminals .
Logical AND Function Adds Flexibility to I/O Expansion.
Facilitates partial or complete control system setup.
Solid-state outputs (excluding Expansion Units).
Detailed LED indications enable easy diagnosis.
TÜV SÜD certification for compliance,
with IEC/EN61508 (SIL3), EN ISO13849-1 (PLe/Safety Category 4).
Approved by UL and CSA G2R-14 AC110.
New unit joins the Series with the following two additional features:
-OFF-delay time of up to 150 seconds can be set .
-Two logical AND connection inputs. Type: Welding / wire type, with right column.
Driving rod: long swing rod type.
Terminal specifications: with wire, the left side.
Contact specifications: 1a.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Actuator: Adjustable roller lever.
Conduit openings: G1/2 (PF1/2).
2NC (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operatiing position indicator pplate and the lever G2R-14 AC110.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMMA 3, 4, 4X, 6P, and 13) G2R-14 AC110.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
G2R-14 AC110 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=G2R-14 AC110&select=5