E32-D15XB type: standard type; resistance to twists and turns,
Specialty: plane shape,
Bending radius (mm): B; R4.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsInput capacity: 16 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common .
Internal I/O common: NPN.
Residual voltage: 1 G6C-1114P-US DC5. 2 V max. (0.5 ADC,
between each output terminal and the G terminal)
G6C-1114P-US DC5
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply G6C-1114P-US DC5.
Output device supply current: 100 mA/point .
Unit power supply current consumption: 80 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 130 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors G6C-1114P-US DC5.
Special wiring tool is not necessary .
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance. Appearance: Square/Projection type LED voltage-reduction lighting,
(with Voltage Reduction Unit) A22L-D.
Output: SPST-NO + SPST-NC.
Lighting: LED.
Operating voltage: 100 VAC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring). G6C-1114P-US DC5.
Lever for easily mounting and removing the Switch Unit .
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounteed using either open-type (fork-type) or closed-type G6C-1114P-US DC5.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).
G6C-1114P-US DC5 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=G6C-1114P-US DC5&select=5