Output: DPDT.
Lighting: LED (with built-in reduced-voltage lighting function).
Operating voltage: 100/110 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia . Body.
Miniature design of 28 D2VW-5-3M. 5 mm, the smallest class in the industry.
Detachable Switch
D2VW-5-3M
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Type of input: AC voltage input.
Output type: transistor; -; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with D2VW-5-3M.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display D2VW-5-3M.
Equipped with the sub pressure gauge for monitoring the operation trend .
External event input can be applied to a variety of measurement and identification situations.
DeviceNetPower supply: AC power supply.
Output method: Transistor output source type.
Inputs points: 18 points.
Outputs points: 12 points.Name: DC Power Supply Unit.
Power supply voltage: 24 VDC.
Output capacity: 5 VDC output capacity, 5.3A;
26 VDC output capacity, 1.3A;
Total, 40W.
Options: 24 V DC service power supply, No;
RUN output, No.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Size: M8(Stainless steel)(See note 2.); Single; Unshielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): Pre-wired.
Body length: Long.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Number of beams: 84.
Protective height: 1680mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Modulee (PDM) makes it easy,
to set functions D2VW-5-3M.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Lightt CCurtain functions D2VW-5-3M.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
D2VW-5-3M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=D2VW-5-3M&select=5