Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals .
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals
D4GL-2FFG-A4).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs D4GL-2FFG-A4.
Mounted relay or solid-state relay has a plug-in terminal .
that is difficult to bend at the time of exchange. Optical system: Diffuse reflective.
Beam shape: Spot beam.
Sensing distance: 300±200 mm.
Resolution: 300 μm.
For the most recent information on models that have been,
certified for safety standards, refer to your OMRON website. Unit: 10 points (6 inputs/4outputs); Connector model D4GL-2FFG-A4.
Inputs: 6 points at 24 VDC .
Outputs: 4 transistor sinking outputs.
Clock: Yes.
Ultra-compact, Thin-profile CPM2C CPU.
Unit with CompoBus/S Master Offering.
High-speed Bus Communications with,
No Complicated Wiring.
Ultra-compact, thin-profile design ideal for on-site,
applications.
Ultra-compact at 40 x 90 x 65 mm (W x H x D) with.
10 I/O points and CompoBus/S Master offers.
versatile expandability to construct systems.
meeting on-site needs.
A large number of expansion I/O points reduces,
system construction cost.
Up to three Expansion Terminals can be,
connected. Furthermore, CompoBus/S Remote,
Terminals can be used for expansion I/O points.
Not only in-panel wiring but also external wiring is,
simplified. Furthermore, the miniaturization of the,
control panel reduces cable, terminal block, and wiring costs.
Easy System Designing, Modification, and Expaan sion D4GL-2FFG-A4.
CompoBus/S Remmote Terminals with high-speed .
bus communications and no complicated wiring.
can be used as expansion terminal blocks with,
minimal modifications as long as room for,
expansion is reserved at the designing stage.
A calendar/clock ensures easyy mmachinery control,
including data collection and error logs with date,
and time stamps D4GL-2FFG-A4. This functionality can be used as,
a weekly timer as well.
D4GL-2FFG-A4 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=D4GL-2FFG-A4&select=5