Power ratings: 120 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 24 V.
Output current *1: 5 A.
Cost-effective Single Phase Power Supply.
Universal input and Safety standards.
for worldwide applications.
Space-saving Compact Design.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC) D4N-9120.
DC input can be available: 90 to 350 VDC.
Operation temperature range: –25 to 60 °C
D4N-9120
Compact Dimension for small space.
Flexible installation by special mounting brackets.
Safety standards:
UL508/60950-1, CSA C22.2 No.107.1/60950-1.
EN50178, EN60950-1.
EMS: Conform to EN61204-3.
EMI: EN55011 Class A.
Three years Warranty D4N-9120. Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A) .
Operation: Alternate operation (Self-holding).
Case color: Light gray.
Output: SPDT.
Lighting: LED; 24 VDC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting) D4N-9120.
included in lineup . Size: 48 x 48mm.
Body: terminal type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event entry point: 2.
Transfer output: -.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 macchines to support a variety of sensorss D4N-9120.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eeexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault
D4N-9120 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=D4N-9120&select=5