Type: 2-Conduit.
Contact configuration: Slow-action MBB contact; 1NC/1NO.
Conduit opening/Connector: G1/2.
Multi-contact, Labor-saving,
Environment-friendly, Next,
generation Safety-door Switch.
Lineup includes three contact models with 2NC/1NO,
and 3NC contact forms and MBB models in addition,
to the previous contact forms 1NC/1NO, and 2NC DRT2-MD32SLH-1-08.
M12-connector models are available, saving on,
labor and simplifying replacement
DRT2-MD32SLH-1-08
Standardized gold-clad contacts provide high,
contact reliability.
Applicable to both standard loads and microloads.
Variety of metallic heads available. Appearance: Round/Full-guard type LED lighting,
(without Voltage Reduction Unit) A22L-G DRT2-MD32SLH-1-08.
Output: SPST-NO + SPST-NC .
Lighting: LED.
Operating voltage: 12 VAC/VDC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks DRT2-MD32SLH-1-08.
Finger protection mechanism on Switch Unit provided as a standard feature .
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). CPU Unit: CP1L-M CPU Units with 30 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Transistor output (sinking);
Inputs, 18; Output, 12.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time valuue can be checked eeasily because operation time,
is indicated from the start of operation DRT2-MD32SLH-1-08.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeenccy, basic,
frequency, and load conditions DRT2-MD32SLH-1-08. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
DRT2-MD32SLH-1-08 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=DRT2-MD32SLH-1-08&select=5