Actuator: Sealed (Booted); One-way action sealed roller arm lever; DC.
Mounting: Side mounting.
General-purpose Enclosed.
Switches with High Breaking.
Capacity and High Durability.
Z General-purpose Basic Switches are built into ZE, ZV,
and ZV2 Switches. They provided high durability and high,
breaking capacity .
X Basic Switches with magnetic blowout are built into XE,
XV, and XV2 Switches
E2E-X14MD15 2M DC models have also been added,
to the series.
Three mounting methods (side, base, and diagonal side),
and many types of actuator are available.
Terminals face the front when the cover is removed for,
easy connection.
Switches with ground terminals have CE marking E2E-X14MD15 2M.
Approved by UL, CSA, and CCC (Chinese standard) .
(Ask your OMRON representative for information on approved models.)Number of beams: 86.
Protective height: 1745mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions E2E-X14MD15 2M. Action indicator: there are.
Applicable load of output: DC5 3A ~ 110V.
Input rated voltage: DC5 ~ 24V.
Insulation: photo coupler.
Zero trigger function: No.
Socket terminal type with same shape as MK type power relay.
New international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with MK (2 pole type).
A model with an action indicator to check the status of the input. Appearance: Rectangular (M16-J).
Lighting: LED without Voltage Reduction Unit, 12 VAC/VDC.
Degree of protection: IP40.
Display color symbol: R: red; Y: yellow; G: green; A: blue;
W: white; PY: pure yellow; PW: pure white.
Cylindrical 16-dia. Indicator.
Same basic design as the A16 Pushbutton Switch. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, connvenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E2E-X14MD15 2M.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact ouutput E2E-X14MD15 2M.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
E2E-X14MD15 2M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E2E-X14MD15 2M&select=5