Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: - .
Event entry point: 2.
Transfer output: output (using control output) E2E-X2ME1 2M.
Communication: -
E2E-X2ME1 2M
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0 E2E-X2ME1 2M. 01 degrees C (to achieve a small size of 48 x 48mm) .
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultTimer input: PNP/NPN universal DC voltage input(4 E2E-X2ME1 2M. 5 to 30 VDC).
Display: 7-segment LCD.
Time range: 999h59min59s ←→ 9999h59.9min(switchable); Black body.
Seven digits, time range 0 to 3999d23.9h.
Dual time range: 999999.9 ←→ 3999d23.9h or,
999h59m59s ←→ 9999h59.9m. Case color: Light gray.
Lighting method: LED; 24 VDC.
Display color symbol: R.O.G.W.
Large Rectangular-bodied Indicators.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting),
included in lineup. Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 2 outputs;
Signal range selection:
Set separately for each output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA; 1/4,00.
Conversion period: 1 ms/point.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.3% of F.S. Current: ±0.5% of F.S.
External connection: Removable teerminal block E2E-X2ME1 2M.
Externall power supply: 24 VDC +10% -15%, 140mA max .
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 24V, 0.14*3.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Anaaloog Input Units for converting analog input,
signals into binary data E2E-X2ME1 2M.
Analog Output Units for converting binary ,
data into analog output signals.
E2E-X2ME1 2M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E2E-X2ME1 2M&select=5