Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 6.4 dia.
Protective tubing length L: 75 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work .
Ideal for the thermal input devices of Temperature Controllers E2E-X2ME2-M1-Z.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal
E2E-X2ME2-M1-Z Output: SPDT.
Lighting: Incandescent lamp.
Operating voltage: 24 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white E2E-X2ME2-M1-Z.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1 E2E-X2ME2-M1-Z. Actuator: Panel mount crossroller plunger .
Type: Micro load.
Compact, General-purpose Horizontal.
Switches.
Models for Microloads Added to Series.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.),
Incorporates a switch with a durable coil spring in a tough,
high precision case.
Compact and uses a single basic switch for applications where,
strength is required.
Models for microloads and models with operation indicators,
added to series.
Terminal protective cover can be switched to wire cable from,
either the left or right.
Sealing characteristics that meet IEC IP67 degree of protection. Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Crossroller plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance ssealed via encapsulatiing material E2E-X2ME2-M1-Z.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfiirmation of operation E2E-X2ME2-M1-Z.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
E2E-X2ME2-M1-Z Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E2E-X2ME2-M1-Z&select=5