Optical system: diffuse type.
Detection distance: 50 positive and negative 5mm.
Beam shape: linear beam.
Beam diameter: 1.0mm * 30 m.
Resolution: 0.25 M.
Cable length: 0.5m. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output .
Control mode: standard or heating cooling E2E-X3D1-M1GJ-T 0.3M.
Auxiliary output points: 2 points
E2E-X3D1-M1GJ-T 0.3M
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event input points: -.
Transfer output: -.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products E2E-X3D1-M1GJ-T 0.3M.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrastCable length L: 1 . 0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode E2E-X3D1-M1GJ-T 0.3M.
Control mode: standard or heating cooling .
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status displaay function, connvenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E2E-X3D1-M1GJ-T 0.3M.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact ouutput E2E-X3D1-M1GJ-T 0.3M.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.