Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 15 W.
Output voltage: 48 V.
Output current: 0.35 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V) E3F2-R4B4-P1-E.
Easy Mounting: Front-mounted type, DIN rail-mounted type are available
E3F2-R4B4-P1-E
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1) E3F2-R4B4-P1-E.
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA) .
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).Fitting materials: Stainless steel (SUS304).
Count: 1.
Accessories: Description, Slotted/Phillips screws M3,
(with spring and plain washers);
Material, Stainless steel (SUS304); Count, 2 E3F2-R4B4-P1-E.
Applicable sensor (mounting pitch on sensor side): E3Z pre-wired model .
Page: Dimensions, 7.
Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 1 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see thhe state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E3F2-R4B4-P1-E.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation E3F2-R4B4-P1-E.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
E3F2-R4B4-P1-E Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E3F2-R4B4-P1-E&select=5