Control output: voltage output (SSR driver).
Auxiliary output: 2 points.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type
E3HS-DS5E2 2M
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating E3HS-DS5E2 2M.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8 E3HS-DS5E2 2M. 5mm). Number of phase: Single-phase.
Control terminal block: Screwless clamp terminal block.
Type: Constant current.
Capacity: 60 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,
and constant-current control.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified. Action mode alarm contact: no lock, B contact.
Category: no auxiliary contact.
Relay number: 2.
Rellay circuit unit suitabble for centralized alarm device of various control circuits E3HS-DS5E2 2M.
MYA combination of multiple MY4 micro power relay, with all kinds of alarm function.
Small, socket type, so it can effectively use the space, repair, maintenance and other operation is ssimmple and convenient E3HS-DS5E2 2M.
By use, roughly divided into 4 types, to adapt to the full range of models.
Lloyd standard certified products (MYA-LA12, -LB12).
E3HS-DS5E2 2M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E3HS-DS5E2 2M&select=5