Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1 dia.
Protective tubing length L: 20 cm.
Lead wire type: Standard.
Lead wire length M: 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E3S-LS3N 2M.
Ideal for the thermal input devices of Temperature Controllers
E3S-LS3N 2M
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Type: printing plate mounting type, with right column.
Driving rod: swing lever type E3S-LS3N 2M.
Terminal specification: printed board, angular .
Contact specifications: 1c.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free E3S-LS3N 2M. Number of beams: 65.
Protective height: 1620mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to seee the state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E3S-LS3N 2M.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation E3S-LS3N 2M.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.