Number of beams: 102.
Protective height: 2040mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A .
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module
E3T-FT13-M1TJ 0.3M
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Size: 48 x 24mm E3T-FT13-M1TJ 0.3M.
Control output 1: relay output.
Control output 2:-- .
Auxiliary output: 2 points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 1 points.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance E3T-FT13-M1TJ 0.3M.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc . .
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately). Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 40 A at 200 to 480 VAC.
Rated input voltage: 5 to 24 VDC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output cuurrents have been,,
added to the G3NA Series E3T-FT13-M1TJ 0.3M.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Prrottective cover for greater safety E3T-FT13-M1TJ 0.3M.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)).
E3T-FT13-M1TJ 0.3M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E3T-FT13-M1TJ 0.3M&select=5