Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use .
Event input points: - E3Z-T82-G0 2M.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade
E3Z-T82-G0 2M
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type E3Z-T82-G0 2M.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV .
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Name: Slice I/O Units; Temperature Input.
(Resistance Thermometers).
Specifications: Temperature input,
(Resistance thermometer:Pt100) 2 points E3Z-T82-G0 2M.
Standards: CE, UC1, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit classification: CJ1 Special I/O Units.
Product name: Process Input Units,
(Isolated type Units with Universal Inputs).
Input points: 4 inputs.
Signal range selection:
Set separately for each input.
Signal range:Universal
inputs: Pt100 (3-wire), JPt100 (3-wire),
Pt1000 (3-wire), Pt100 (4-wire), K, J,
T, E, L, U, N, R, S, B, WRe5-26, PL II,
4 to 20 mA, 0 to 20 mA, 1 to 5V, 0 to 1.25V,
0 to 5V, 0 to 10V, ±100 mV selectable range,
-1.25 to 1.25 V, -5 to 5 V, -10 to 10V,
±10V selectable range, potentiometer.
Conversion speed (resolution): Resolution
(conversion speed): 1/256,000 (conversion cycle:
60 ms/ 4 inputs) 1/64,000 (conversion cycle:
10 ms/4 inputs) 1/16,000 (conversion cycle:
5 ms/4 inputs).
Accuracy at ambient temperature of 25°C:
Standard accuracy: ±0.05% of F.S.
External connection: Removable terminal bllock E3Z-T82-G0 2M.
No. of unit nummbers allocated: 1 .
Current consumption: 5V, 0.30A; 24V, --.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inpuut channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) E3Z-T82-G0 2M.
All inputs are isolated.
E3Z-T82-G0 2M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E3Z-T82-G0 2M&select=5