Specification: Thermocouple input (K, J, L, T, R, S, B),
heater burnout alarm,
ON/OFF or advanced PID control,
manual operation,
transistor (NPN) output, 2 loops.Item: Advanced models, ATC function.
Functions: ATC (Active Threshold Control).
Model: PNP output.
Variable Laser Beam for Spot, Line, or Area Detection .
Long-distance detection (diffuse reflective: 1 m, retro-reflective: 7 m)
E52-P55C D=10
Beam shape selectable from spot, line, and area types to match various applications.
Adjustable spot diameter.
Adjustable optical axis.
The E3DC-LDA0, which supports the EtherCAT Sensor.
Communications Unit and the CompoNet Sensor.
Communications Unit, is also included in product lineup E52-P55C D=10. C1000H-SL SYSMAC BUS SYSMAC LINK C1000H-SLK21.Size: 48 x 24mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485 E52-P55C D=10.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance .
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately). The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventivee maintenance function is increased,
Further performance improvement E52-P55C D=10.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee ddisplay PV/SV E52-P55C D=10.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
E52-P55C D=10 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E52-P55C D=10&select=5