Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 32 outputs;
Maximum switching capacity, 12 to 24VDC, 0.5A;
Commons, 16 points, 1 common;
External connection, MIL connector.
No. of words allocated: 2 words.
Current consumption: 5V, 0 . 14A; 24V, --.
Standards: UC1, N, L, CE E5AN-HPRR201BD-FLK AC/DC24.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications
E5AN-HPRR201BD-FLK AC/DC24
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system E5AN-HPRR201BD-FLK AC/DC24.
throughput. Name: Basic Unit (temperature control) *1 .
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 4.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2.
Control outputs 3 and 4: Voltage output: 2 points (for SSR drive) *2.
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, None E5AN-HPRR201BD-FLK AC/DC24.
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485 .
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirementts E5AN-HPRR201BD-FLK AC/DC24.
Conneect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise .
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calcullatte the PID constants with the step,
response method E5AN-HPRR201BD-FLK AC/DC24.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.
E5AN-HPRR201BD-FLK AC/DC24 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E5AN-HPRR201BD-FLK AC/DC24&select=5