Power rating: 350 W.
Input voltage: 100 to 120 VAC, 200 to 240 VAC (allowable range: 90 to 132 VAC,
180 to 264 VAC, or 254 to 373 VDC(Select with the switch.)*2).
Output voltage: 5 V VDC.
Output current: 60 A.
Built-in fan: Yes.
Model with terminal block facing forward.
High Reliability at a Reasonable Cost .
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation E5CSZ-R1T-B AC100-240.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage
E5CSZ-R1T-B AC100-240
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life E5CSZ-R1T-B AC100-240. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications .
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W E5CSZ-R1T-B AC100-240. Modular panel direct mounting type, easy to install and maintain the basic type .
The relay unit is modular and easy to maintain.
With LED action display function, so that the state of action at a glance.
Tropical treatment and high temperature.
Stable detection can be achieved with high ambient temperature.
Type: I type, water level display and alarm (No 2 wire in I).
Package product name: 61F-I base * 1, 61F-11_ unit * 2.
Purpose: General use. The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maaintenance funcction is increased,
Further performance improvement E5CSZ-R1T-B AC100-240.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5CSZ-R1T-B AC100-240.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
E5CSZ-R1T-B AC100-240 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E5CSZ-R1T-B AC100-240&select=5