The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function
E5EN-HAA2HH03BF-FLK AC100-240
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E5EN-HAA2HH03BF-FLK AC100-240.
E5CN-U (insert type) add analog input and current output type .
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay E5EN-HAA2HH03BF-FLK AC100-240. Lead wire length: 4m.
A Wide Variety of High-precision.
Temperature Sensors .
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. MITSUBISHI motor produced PLC connection cable.
Size: A, 1000mm; B, 750mm.
Input use.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Number of beams: 26.
Protective height: 520mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easyy,
to set functions E5EN-HAA2HH03BF-FLK AC100-240.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Lightt CCurtain functions E5EN-HAA2HH03BF-FLK AC100-240.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
E5EN-HAA2HH03BF-FLK AC100-240 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E5EN-HAA2HH03BF-FLK AC100-240&select=5