Specifications: Input, NPN (+ common), 8 points.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: Supplied from the communications connector.
Environment-resistive (IP67) I/O.
Terminals with Troubleshooting .
Functions such as Sensor Power E5EN-HSS2HH03B-FLK AC100-240.
Supply Short-circuit Detection.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities
E5EN-HSS2HH03B-FLK AC100-240
High degree of environmental resistance with dust-proof,
and drip-proofconstruction.
Power supply wiring is not required for input devices E5EN-HSS2HH03B-FLK AC100-240.
Connect heavy-load devices (up to 1 . 5 A).
Power supply wiring is not required for input devices such as sensors.
(Power supply wiring is required for output devices.)
Detects ground faults or disconnects and notifies the Master.
Type: rectangle.
Screen mode: 2 short axis segmentation.
Light way: LED.
Power supply voltage: 28V
Operating part left color: white E5EN-HSS2HH03B-FLK AC100-240.
Operating part right color: white.
Square 40mm body of the indicator light series .
The same type as the A3S series button switch.
Easy to install from the front panel and no tools to carry out the lamp replacement. Size: 48 x 24mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 2 points.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenannce perfformance E5EN-HSS2HH03B-FLK AC100-240.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsiion Village (sold separately) connected to the computer after,
No power connection can be set E5EN-HSS2HH03B-FLK AC100-240.
It can be easily set by CS-Thermo (sold separately).
E5EN-HSS2HH03B-FLK AC100-240 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E5EN-HSS2HH03B-FLK AC100-240&select=5