Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 3 points (common universal).
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: - .
Communication: -.
Event input: 4 points E5EN-HTAA2HH01B-FLK AC100-240.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility
E5EN-HTAA2HH01B-FLK AC100-240
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility E5EN-HTAA2HH01B-FLK AC100-240.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications .
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set E5EN-HTAA2HH01B-FLK AC100-240.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication .
Combined temperature control device through component communication. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E5EN-HTAA2HH01B-FLK AC100-240.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation E5EN-HTAA2HH01B-FLK AC100-240.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
E5EN-HTAA2HH01B-FLK AC100-240 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E5EN-HTAA2HH01B-FLK AC100-240&select=5