Type: 1C contact type.
Shape: square.
Terminal shape: terminal for printed board.
Action: instantaneous.
Display mode: do not display.
Operation Department color: black.
Large capacity compact type push button switch.
Can also be used as a power switch with a large capacity cut.
Can be switched from micro load (minimum applicable load 1mA DC5V) to large capacity load E5ER-CT3DB-FLK AC100-240V. Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC
E5ER-CT3DB-FLK AC100-240V
Cable: SJT(O) cable *3.
Actuator: Plastic rod.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models E5ER-CT3DB-FLK AC100-240V. )
Sealing characteristics that meet IEC IP67 degree of protection .
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables E5ER-CT3DB-FLK AC100-240V.
Multiple mounting possible with Switches with Plungers .
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Structure: Relays with Plug-in Terminals, With operation indicators.
Classification: Standard models Compliance with Electrical,
Appliances and Material Safety Act.
Number of poles: 3.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety.
standards and with the Electrical Appliances and,
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joined thhe series E5ER-CT3DB-FLK AC100-240V.
The lineup also includes models that are compliant,
with the LR and VDE safety standards .
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 11000/110 VDC) E5ER-CT3DB-FLK AC100-240V.
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC).
E5ER-CT3DB-FLK AC100-240V Operation manual / Instructions / Catalog download link: