Specifications: Inputs;
NPN (+ common);
16 points.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
Used in combination with Interface,
Conversion Boards (e . g., D-Sub) to,
connect to a wide range of interfaces E6HZ-CWZ1X 1000P/R 0.5M.
35 x 60 x 80 mm (W x D x H)
E6HZ-CWZ1X 1000P/R 0.5M Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A).
Operation: Momentary operation (Self-resetting).
Case color: Light gray.
Output: DPDT.
Lighting: LED; 5 VDC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted E6HZ-CWZ1X 1000P/R 0.5M.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness .
Three-color models (green, orange, red; chameleon lighting).
included in lineup. Contact type: Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A).
Operation: Momentary operation (Self-resetting).
Case color: Black.
Output: SPDT.
Lighting: LED; 24 VDC.
Pushbutton color symbol: R.O E6HZ-CWZ1X 1000P/R 0.5M. G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity .
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting).
included in lineup. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
2-Wire Transmitter Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 1 to 5 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabledd major savinngs in cost and space compared,
with previous systems E6HZ-CWZ1X 1000P/R 0.5M.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUss,
to construct complete process control systems E6HZ-CWZ1X 1000P/R 0.5M.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
E6HZ-CWZ1X 1000P/R 0.5M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E6HZ-CWZ1X 1000P/R 0.5M&select=5