Power supply voltage: 100 to 240 VAC.
Output: Relay.
Timer function: No.
Features: Single-function with two inputs/one output (AND/OR operation).
High-speed response of 0.1 ms.
Ideal as a two-input Controller.
Power source for the Sensor can be supplied up to 200 mA.
Ultra-slim body with 30-mm width.
Multi-function model equipped with timer functions also available.
Power ratings: 120 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 5 A.
Alarm output *2: Sinking.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication OMRON S3D2-AK .
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that
S3D2-AK
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) OMRON S3D2-AK .
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter OMRON S3D2-AK .
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input S3D2-AK OMRON.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) S3D2-AK OMRON.
LED operation indicator.
UL/CSA approval (SDV-F@). Suitable cable dia: 4 mm dia. model (4 to 5 mm dia.).
Suitable core size: 0.5 max.
Suitable Sheath material: PVC, PE, PUR.
Cable connection direction: L-shaped.
Connection method: Soldering.
DC: Model.
Minimum order: 50.
Water- and Environment-resistive FA S3D2-AK OMRON.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements andd ensure a,
94V-0 fire retardant rating S3D2-AK .
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of CConnector Assembly: Crimping, soldering, and screw-on OMRON S3D2-AK .
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.