LK166
Home >> Products >> OMRON >> Inverter >> 3G3AX-NFO05 OMRON Output noise filter

3G3AX-NFO05 OMRON Output noise filter

Brand: OMRON
Name: Output noise filter
Model: 3G3AX-NFO05
Power supply: 3 phase 3 line rated voltage 500V AC.
Rated current: 75A.
Weight: 5.7KG.
Used to reduce the noise generated by the inverter.
Try to be close to the transducer for connection.

Function name: 3 phase 200V.
Power: 3.7KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 2.0KG.
Dimension (w * h) 128mm *:140.
Outline dimension (deep):170.5mm.
Mechanical automation concept 3G3AX-NFO05 OMRON.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication 3G3AX-NFO05
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Function name: 3 phase 400V.
Power: 0.4KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage) 3G3AX-NFO05 OMRON.
Built in brake unit (brake resistance needs to be matched).
Weight: 1.5KG.
Dimension (w * h) 128mm *:108.
Outline dimension (deep):143.5mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function 3G3AX-NFO05 OMRON.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Cable length: 3m.
A digital operator is installed in a place far away from the transducer. Frequency converter input power: 3 phase AC400V.
Weight: 7.0KG.
Standard applicable line diameter: 38 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. The communication unit can connect the multi function small transducer EtherCAT to the MX2 network.
The communication unit passed the EtherCAT conformance test.
Power supply: through the inverter power supply.
Protection structure: open type (IP20). Speciffication: medium capacity type 3G3AX-NFO05.
Impact resistance: 600W.
Resistance to impact resistance: 35.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down.
Alarm output terminal of braking resisttor 3G3AX-NFO05.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed.


...More relevant models >>>>