Connection type: PCI, wired CLK.
I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 60K steps.
Data memory capacity: 128K words (DM: 32K words, EM: 32K words ×3 banks)Unit type: CS1 Special I/O Units.
Connected ID System: V680 Series;
2 Heads.
External power supply : 24 VDC.
No. of unit numbers used: 2 unit number OMRON 3G8F7-CLK23-E.
Current consumption: 5V, 0.32A; 26V, --;
External, 0.36A.
Communication Unit Dedicated for RFID,
V680 Allowing Direct Connection to,
OMRON PLC CJ/CS/NJ-series
3G8F7-CLK23-E
Communication unit for connecting RFID,
V680-series, which can be used around,
the world, directly to PLC.
Allows batch transfer of data up to 32 kbytes.Name: CS1D CPU Unit for Single CPU Systems.
Specifications: Number of I/O points,
5,120 points (7 Racks);
Program capacity, 250 Ksteps;
Data Memory, 448 Kwords(DM: 32 Kwords,
EM: 32 Kwords×13 banks);
LD execution time, 0 OMRON 3G8F7-CLK23-E. 02 μs;
Duplex CPUs, --;
Interrupt functions, OK.
Current consumption: 5V system, 0.82A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables.
I/O bits: 5, 120 (Expan-sion Racks: 7) OMRON 3G8F7-CLK23-E.
Program capacity: 20K steps.
Data memory capacity: 64K words (DM: 32K words, EM: 32K words ×1 banks).I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 30K steps.
Data memory capacity: 64K words (DM: 32K words, EM: 32K words ×1 banks).I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 250K steps.
Data memory capacity: 448K words (DM: 32K words, EM: 32K words ×13 banks).Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
250 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost annd space compared,
with previous systems 3G8F7-CLK23-E.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems 3G8F7-CLK23-E.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.