LK166
Home >> Products >> MITSUBISHI >> Ans/QnAs series PLC >> Computer communication module >> A1SJ71PB92D | MITSUBISHI Profibus interface module A1SJ71PB92D

A1SJ71PB92D | MITSUBISHI Profibus interface module A1SJ71PB92D

Brand: MITSUBISHI
Name: Profibus interface module
Model: A1SJ71PB92D
Available network: Profibus-DP.
Function: Master station.
The A1SJ71PB96F and A1SJ71PB92D modules allow a PLC ANS to connect to the Profibus system,
Meet the CE standard, using SWOIX/ProfiMap special programming software.
A1SJ71PB96F compatible with Profibus-FMS, as a master or client;
A1SJ71PB92D compatible with Profibus-DP, can be used as a master to control the remote Profibus-DP I/O.

Input and output points: 1024 points.
Input / output data points: 8192 points.
Program capacity: 60k.
Basic command processing speed (LD command) S:0.2.
PLC in the program execution stage: according to the order of the user program order to store the order of each instruction,
After the corresponding operation and processing, the result is written to the output status register,
The contents of the output status register are changed with the execution of the program MITSUBISHI A1SJ71PB92D A1SJ71PB92D
Output refresh phase: when all instructions are executed,
The output status register is sent to the output latch in the output refresh stage,
And through a certain way (relay, transistor or transistor) output, drive the corresponding output equipment MITSUBISHI A1SJ71PB92D. Input points: 32 points.
Input voltage and current: 7mA DC24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 24 points.
Output voltage: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public side.
34 point terminal station.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control MITSUBISHI A1SJ71PB92D.
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control A1SJ71PB92D MITSUBISHI.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control A1SJ71PB92D MITSUBISHI.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power A1SJ71PB92D MITSUBISHI.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc..
At the same time, there is also an analog input unit (A/D),
Transform these standard electrical siggnals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal A1SJ71PB92D.
So the standard telecommunication number, the conversiion between the number of operations to use a variety of computing MITSUBISHI A1SJ71PB92D.
This requires the resolution of the analog unit and the standard electrical signal.


...More relevant models >>>>