LK166
Home >> Products >> OMRON >> CJ2/CJ1 PLC >> Other units >> CJ1W-CIF21 OMRON CJ1W-CIF21

CJ1W-CIF21 OMRON CJ1W-CIF21

Brand: OMRON
Name:
Model: CJ1W-CIF21
CompoWay/F adapter for communications with Omron Process and Temperature Controllers and Panel Meters.

Unit type: CJ1 Basic I/O Units.
Product name: DC Input Units.
Specifications: I/O points, 32 inputs;
Input voltage and current: 24 VDC, 4.1 mA;
Commons, 16 points, 1 common; External connection,
MIL connector; No. of words allocated, 2 word.
Current consumption: 5V, 0.09A; 24V, --.
Standards: UC1, N, L, CE OMRON CJ1W-CIF21.
A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications CJ1W-CIF21
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memory in the CPU Unit.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available. These units can,
help to increase system throughput. Unit classification: CJ1 Special I/O Units.
Product name: Isolated type DC Input Units OMRON CJ1W-CIF21.
Input points: 2 inputs.
Signal range selection: DC voltage:
0 to 1.25 V, -1.25 to 1.25 V, 0 to 5 V,
1 to 5 V, -5 to 5 V, 0 to 10 V, -10 to 10 V,
±10 V selectable range DC current:
0 to 20 mA, 4 to 20 mA.
Conversion speed (resolution): Conversion,
speed: 10 ms/2 inputs, Resolution: 1/64,000.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0 OMRON CJ1W-CIF21. 05% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 24V, 0.09A.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated. Type: CJ1 Special I/O Unit.
Name: CompoBus/S Master Unit.
Specifications: Communications functions,
Remote I/O communications; No. of I/O points,
256 max. (128 inputs and 128 outputs);
Max. Units mountable per CPU Unit: 40.
No. of unit numbers allocated: 1 or 2(variable).
Current consumption : 5V, 0.15A; 24V,--.
Standards: UC1, N, L, CE.
CompoBus/S is a high-speed I/O bus. Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 8 inputs;
Signal range selection: 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 to 10 V, 4 to 20mA;
1/4,000(Settable to 1/8,000)*2 .
Conversion period: 1 ms/point,
(250 μs/point can also be set.)*2.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F. S. Current: ±0.4% of F.S.
Externall connection: Removable terminal block CJ1W-CIF21.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.42A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Anaalog Input Units for converting analog input,
signals into binary data CJ1W-CIF21.
Analog Output Units for converting binary ,
data into analog output signals.


...More relevant models >>>>