Unit type: CJ1 Basic I/O Units.
Product name: DC Input Units.
MIL connector; No. of words allocated, 4 word.
Current consumption: 5V, 0.09A; 24V, --.
Standards: UC1, N, L, CE.
Different Applications.
I/O memory in the CPU Unit.
CJ1W-ID233 are now available. These units can,
help to increase system throughput.
Product name: CJ-series I/O Control Unit.
Specifications: One I/O Interface Unit is,
required on each Expansion Rack.
Connecting Cable: CS1W-CN@@3 Expansion,
Connecting Cable Mount to the right of,
the Power Supply Unit.
Current consumption: 5V , 0.02A;
24V, --.
Standards: UC1, N, L, CE.
Expand CJ/NJ-series with These Units CJ1W-ID262 OMRON.
To expand a CJ/NJ-series Controller,
connect an I/O Control Unit to the CPU Rack,
and I/O Interface Unit to the Expansion Rack,
and connect the two Units with I/O Expansion Cable
CJ1W-ID262 Unit type: CJ1 CPU Bus Units.
Product Name: Position Control,
Unit with MECHATROLINK-II interface.
Specifications: Control commands,
executed by MECHATROLINK-II,
synchronous communications CJ1W-ID262 OMRON.
Direct operation by ladder programming.
Control mode: Position control,
speed control or torque control;
No. of axes: 16 axes.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.36A; 24V,--.
Standards: UC1, CE.
Decrease TCO with Simple Operation,
Reduced Wiring, Batch Settings,
and Batch Management.
Control Servos for up to 16 axes in,
a motion network with one Position,
Control Unit that supports MECHATROLINK-II CJ1W-ID262 OMRON.
MECHATROLINK-II is a registered trademark,
of the MECHATROLINK Members Association. Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 4 loops;
Temperature sensor inputs: Platinum ,
resistance thermometer input(JPt100, Pt100);
Control outputs: Open collector PNP outputs (pulses).
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output. Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications,
Units High-speed type.
Specifications:Communications Interface,
1 RS-232C port and 1 RS-422A/485 port;
Communications functions,
The following functions can be selected,
for each port with an CJ system:
Protocol macro, Host Link, NT Links (1:N mode),
Serial Gateway, No-protocol, Modbus-RTU Slave,
The following functions can be selected,
for each port with an NJ system: Protocol macro,
Serial Gateway, No-protocol, Modbus-RTU Slave.
No. of unit numbers allocated: 1.
Current consumption : 5V, 00 CJ1W-ID262. 36A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485,, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol CJ1W-ID262.