Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 3NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC.
Number of beams: 45.
Protective height: 2220mm.
Model: NPN output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions D4N-1D2HR OMRON. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; G1/2
D4N-1D2HR
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability D4N-1D2HR OMRON.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Number of beams: 88.
Protective height: 1790mm.
New Standard of Safety Light.
Curtain,Offering Both Robustness.
and Reliability.
Robust and compact.
New muting function to increase both productivity and safety D4N-1D2HR OMRON.
All models designed for global use. PNP/NPN selection by.
DIP switch.
Conforming to major international standards including.
Chinese standard GB 4584. Actuator: One-way roller arm lever (vertical).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 3NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Actuator: Plunger.
Conduit openings: G1/2 (PF1/2).
2NC (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever D4N-1D2HR.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) D4N-1D2HR.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.