Dimensions: A, 300mm; B, 300mm.
Model: Yellow.
Safety outputs: SPDT-NO.
Auxiliary outputs: SPDT-NC.
Rated voltage: 24 VDC.
Terminal block type: Screw terminals.
New Safety Mat That Is Easy to.
Install and Maintain.
Simple connection allows multiple mats to be joined together.
A wide variety of mat sizes are available OMRON D4SL-N2EFA-D4N.
Obtained EN1760-1 and EN ISO13849-1 (PLd/Safety.
Category 3) certification
D4SL-N2EFA-D4N
Complies with North American safety standards,
including ANSI/RIA15.06-1999. Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards OMRON D4SL-N2EFA-D4N.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) OMRON D4SL-N2EFA-D4N.
Certified standards: UL, EN (TÜV), and CCC. Number of beams: 66.
Protective height: 1320mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Number of beams: 62.
Protective height: 1240mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. D4SL-N2EFA-D4N.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Lightt Curtain functions D4SL-N2EFA-D4N.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.