LK166
Home >> Products >> OMRON >> Master slave station products >> DeviceNet >> DRT1-COM | OMRON DRT1-COM Communications Unit

DRT1-COM | OMRON DRT1-COM Communications Unit

Brand: OMRON
Name: Communications Unit
Model: DRT1-COM
Power supply voltage: 24 VDC.
Connects to a Total Maximum of Eight,
Digital I/O, Analog I/O, and Relay Output,
Units Compatible with MULTIPLE I/O,
TERMINAL.
Allows flexible combinations of I/O points.
Covering a total cable length of 3 m.
DIN track mounting.

Specifications: Inputs; NPN (+ common);
16 points.
I/O connections: M3 screw terminals.
Rated internal circuit power supply voltage:
Supplied from Basic Unit.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals OMRON DRT1-COM.
Easy wiring with no sharing of terminals.
Easy-to-understand wiring locations DRT1-COM
No relay terminal block terminals required.
Detachable cassette-type circuit sections. Input capacity: 16 points.
Internal I/O common: NPN.
ON voltage: 15 VDC min.
(between each input terminal and the V terminal)
OFF voltage: 5 VDC max.
(between each input terminal and the V terminal)
OFF current: 1 OMRON DRT1-COM. 0 mA max.
Input current: 6.0 mA max./input (at 24-VDC);
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms, 1 ms,
2 ms, 4 ms, 8 ms, 16 ms, 32 ms (Default setting: 1 ms).
Number of circuits per common: 16 inputs/common.
Input indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply OMRON DRT1-COM.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current con sumption: 5 mA max.
(for 20.4 to 26 DRT1-COM OMRON. 4-VDC power supply voltage)
Weight: 180 g max.
Expansion functions: Enabled.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications DRT1-COM OMRON.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansion unit per one I/O terminal unit DRT1-COM. )
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing DRT1-COM OMRON.
Selectable node address setting methods:
setting with rotary sswitch and with tool software OMRON DRT1-COM.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance.


...More relevant models >>>>