LK166
Home >> Products >> OMRON >> Master slave station products >> DeviceNet >> DRT2-ID16ML-1 OMRON MIL Connector Terminals with Transistors

DRT2-ID16ML-1 OMRON MIL Connector Terminals with Transistors

Brand: OMRON
Name: MIL Connector Terminals with Transistors
Model: DRT2-ID16ML-1
Specifications: Inputs;
PNP (- common);
16 points.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H).

Input capacity: 16 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: PNP.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the V terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common DRT2-ID16ML-1 OMRON.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation DRT2-ID16ML-1
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 80 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 130 g max.
Expansion functions: No DRT2-ID16ML-1 OMRON.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing DRT2-ID16ML-1 OMRON.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.
Specifications: Inputs, PNP (- common), 8 points.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications. connector.
Rated I/O power supply voltage: 24 VDC.
Remote I/O Terminals with High.
Degree of Environmental Resistance.
(IP67) in Product Lineup Including.
Economical Input, Output, and Mixed I/O Models.
Commonn Smart Slave functionality provides strong support for equipment,
operation status monitoring and effective maintenance DRT2-ID16ML-1.
High degree of environmental resistance with dust-proof and drip-proof,
construction. (IP67)
Models with one cconnector for two outputs are available to make easier,
connection with hydraulic valve devices DRT2-ID16ML-1.
(Models with 16 outputs and models with 16 mixed I/O)


...More relevant models >>>>