Operating method: Incrementing, decrementing, and reversible (UP/DOWN A to F).
Mounting method: Flush mounting.
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L).
Memory backup: No.
Display: Yes (8-mm high 7-segment LED).
Models: 8 digits.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches.
A draw-out construction enables maintenance without rewiring.
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking.
Operation/resetting system: Time-limit operation/self-resetting.
Time-limit contact: DPDT(for power switching).
Time ranges: 0.04 s to 3 h.
Supply voltage: 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 100 to 110 VDC.
Mounting: Surface/DIN-track mounting (with socket).
Miniature Timer Compatible with the MY OMRON H7AN-RT8.
Relay.
UL listed when used with a Push-In Plus Terminal Block Socket
H7AN-RT8
Conforms to CSA, CE Marking, CCC and LR.
Black design with power supply terminals on top and contact output,
terminals on bottom.
Large transparent time setting knob facilitates time setting.
A flat-blade and Phillips screwdriver can also be used for time setting.
Semi-multi power supply voltage. Count input: PNP/NPN universal DC voltage input(4 OMRON H7AN-RT8. 5 to 30 VDC).
Max. counting speed: 30 Hz ←→ 1 kHz(switchable).
Display: 7-segment LCD.
Model: Black body.
Eight-digits, counting range 0 to 99999999.
Dual input speed: 30 Hz ←→ 1 kHz,
(except for AC/DC multivoltage input models). Timer input: AC/DC multi-voltage input(24 to 240 VAC/VDC).
Display: 7-segment LCD.
Time range: 999999.9h ←→ 3999d23 OMRON H7AN-RT8. 9h(switchable); Light-gray body.
Seven digits, time range 0 to 3999d23.9h.
Dual time range: 999999.9 ←→ 3999d23.9h or,
999h59m59s ←→ 9999h59.9m. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with H7AN-RT8 OMRON.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Relay contact: H; PASS1c, L, each 1c H7AN-RT8 OMRON.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time H7AN-RT8 OMRON.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum can be measured from 10ms to 320Operation/resetting system: Time-limit operation/self-resetting.
Operation mode: ON-delay operation.
Terminal: 8-pin round socket.
Time-limit contact: SPDT.
Instantaneous contact: SPDT.
Mounting: Surface mounting/track mounting; Flush mounting.
DIN-sized (448 x 48, 45 x 75 mm) Timer with H7AN-RT8.
Digital Setting and LCD Display.
Dual power supplies for free AC/DC.
Eight operation modes selectable with one unit.
Any desired time can be set digitally within a range from 0.1,
seconds to 9,9900 hrs OMRON H7AN-RT8.
Four external signal inputs.
ON/OFF indicator for control output and bar indicator for,
remaining time.
Conforms to UL, CSA, and CE marking.