Name: Laser Reflectors, Standard.
Ambient operating temperature range: -10 to 55°C (No icing and no condensation).
Ambient storage temperature range: -25 to 70°C (No icing and no condensation).
Ambient operating humidity range: 35 to 85% (No condensation).
Ambient storage humidity range: 35 to 85% (No condensation).
Output configuration: DC switching NPN (normally open or closed selectable).
Sensing method: Through-beam.
Sensing distance: 50 cm.
Capable of Setting the Sensing Range.
Using an Ultrasonic Beam.
Ensures the stable detection of a variety of objects,
regardless of the color, transparency, or material OMRON E39-R22.
(metallic or non-metallic) of the objects.
Limits the ultrasonic beam width to 8°, thus,
detecting minute objects as small as 2 x 2 cm
E39-R22
Detects objects smoothly while largely suppressing,
interference from background objects.
Sealed to resist dust and dirt and emits ultrasonic,
waves at a frequency of approximately 200 kHz,
thus providing high immunity from impact and,
environmental noise OMRON E39-R22. E3F3-D61M detection method: diffuse reflection type,
Wire lead out type,
Type: metal appearance; NPN output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologySize: M8(Stainless steel)(See note 2.); Single; Shielded.
Sensing distance: 1.5 mm.
Connecting method (See note 1 OMRON E39-R22. ): Pre-wired.
Body length: Long.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Item: Advanced models, Twin-output model.
Functions: Area output, open circuit detection, differential operation.
Communications Unit Applicable Sensor: E3X-ECT, E3X-CRT.
Proximity Sensor with Separate.
Amplifier Enables Easily Making High.
precision Sensitivity Settings.
Wide variety of Sensor Heads to select according to the,
application. Flexible cables are used between Preamplifiers,
and Amplifier Units of the Sensor Heads.
High resistance to changes in ambient temperature.
Temperature characteristics of 0.08%/°C (for 5 E39-R22. 4-dia. models).
Make simple and reliable detection settings with micron,
level precision using the teaching function.
Check the sensing excess gain level on the digital display.
Support for high-precision positioning and screening witth,
fine positioning to maximize variations E39-R22.
The E2C-EDA0 supports an EtherCAT Sensor,
Communications Unit or CompoNet Sensor,
Communications Unit.