LK166
Home >> Products >> OMRON >> Temperature controller >> input device >> E52-CA20AF D=3.2 2M OMRON E52-CA20AF D=3.2 2M

E52-CA20AF D=3.2 2M OMRON E52-CA20AF D=3.2 2M

Brand: OMRON
Name: Temperature Sensor
Model: E52-CA20AF D=3.2 2M
Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 20 cm.
Lead wire type: Standard.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal.

Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater OMRON E52-CA20AF D=3.2 2M.
Event entry point: 2.
Transfer output: - E52-CA20AF D=3.2 2M
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm) OMRON E52-CA20AF D=3.2 2M.
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultSize: 48 * 48mm, terminal type OMRON E52-CA20AF D=3.2 2M.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E52-CA20AF D=3.2 2M.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E52-CA20AF D=3.2 2M.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.


...More relevant models >>>>