Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 8 dia.
Protective tubing length L: 75 cm.
A Wide Variety of High-precision.
Temperature Sensors.
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
and also according to the type and shape of the terminal.
Size: 1/8 DIN 48 × 96 × 78(W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 3.
Control output: Voltage output(for driving SSR).
Functions: Heater burnout, No; Mounting option units, No.
Previous model: E5EZ-Q3 E5EZ-A3 + E53-AZQ E52-CA75B-N D=8 OMRON.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better
E52-CA75B-N D=8
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protocol called Modbus is installed in the,
models with communications E52-CA75B-N D=8 OMRON.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: -- E52-CA75B-N D=8 OMRON.
Communi cations: RS-485.
Previous model: Thermocouple input, E5GN-Q03TC-FLK;
Resistance thermometer input, E5GN-Q03P-FLK.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status off the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E52-CA75B-N D=8.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E52-CA75B-N D=8.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.