Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 3.2 dia.
Protective tubing length L: 50cm.
Lead wire type: Heat resistive.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
and also according to the type and shape of the terminal.
Size: 48 x 24mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: - OMRON E52-IC50AY D=3.2 NETU 1M.
Event input: 2 points.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance
E52-IC50AY D=3.2 NETU 1M
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance OMRON E52-IC50AY D=3.2 NETU 1M.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set OMRON E52-IC50AY D=3.2 NETU 1M.
It can be easily set by CS-Thermo (sold separately). Name: Temperature Controller (See note 1.).
Power supply: 24 VDC.
No. of control points: 2.
Control output: Transistor output.
Auxiliary output: Transistor output: 2 pts (sourcing) E52-IC50AY D=3.2 NETU 1M OMRON.
Functions: Heater burnout alarm (See note 3.), Heating or heat/cool,
control is selectable (See note 4 E52-IC50AY D=3.2 NETU 1M OMRON. )Event input: 1 point per Unit.
Communications functions: RS-485.
Input type (See note 5.): Platinum resistance thermometer.
New DIN Track Mounting Temperature.
Controller.
Two channels of temperature control available despite width of,
only 22.5 mm.
The Temperature Controller itself can be replaced without,
changing terminal wiring E52-IC50AY D==3 E52-IC50AY D=3.2 NETU 1M. 2 NETU 1M OMRON.
Use in combination with a compact Setting Display Unit to,
reduce communications programming requirements.
Front-panel LED indicators for easy operation monitoring.
Power supply and communicatiions wiring not required between,
Units when mounted side-by-side OMRON E52-IC50AY D=3.2 NETU 1M.
CompoWay/F communications protocol supported.
UL, CSA, and CE Marking compliance.