LK166
Home >> Products >> OMRON >> Temperature controller >> Universal temperature controller >> E5AC-QX2DSM-010 | OMRON Digital temperature controller E5AC-QX2DSM-010

E5AC-QX2DSM-010 | OMRON Digital temperature controller E5AC-QX2DSM-010

Brand: OMRON
Name: Digital temperature controller
Model: E5AC-QX2DSM-010
Size: 96 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points.
Communication: -.
Event input: 4 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve.

Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function OMRON E5AC-QX2DSM-010.
Event entry point: 2.
Transfer output: transfer output (special terminal) E5AC-QX2DSM-010
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0 OMRON E5AC-QX2DSM-010. 01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output OMRON E5AC-QX2DSM-010.
Through the infrared port can be carried out from the front of the communication E5AC-QX2DSM-010 OMRON.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Size: 96 × 96 mm E5AC-QX2DSM-010 OMRON.
Control type: Position-proportional control (1 loop).
Control mode: Single-loop position-proportional control (See note.).
Outputs(control/transfer): Relay output,
(1 open, 1 close) and 1 current (transfer) output.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, None; Serial communications, Yes E5AC-QX2DSM-010 OMRON.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using modeels with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E5AC-QX2DSM-010. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,

root calculation and broken-line approximation) OMRON E5AC-QX2DSM-010.
DeviceNet Communications.
Data setting and monitoring can be performed without special programming.