Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve.
Programmable Controllers Join the Series!
Program up to 256 segments and take advantage of the high cost performance,
of the new LCD that improves both the field of view and contrast.
Set up to 8 programmed patterns with up to 32 segments (steps) each.
High-resolution display with 5 digits/0.01°C display OMRON E5EC-CC2ASM-013.
High-speed sampling cycle of 60 ms.
High Accuracy.
Thermocouple/Pt input: ±0
E5EC-CC2ASM-0131% of PV,
Analog input: ±0.1% FS,
Universal inputs on all models (thermocouple, PT, or analog,
input) to handle various sensors with one Controller. Models,
also available with Remote SP.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/RESET, and alarms) and the PV or SV OMRON E5EC-CC2ASM-013.
Flexible contact outputs with logic operations (AND, OR, and,
delays) set from the Support Software (CX-Thermo version,
4.3). Program settings can be managed.
An infrared ports enables communications from the front panel.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter OMRON E5EC-CC2ASM-013.
Model available with position-proportional control. Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: -- E5EC-CC2ASM-013 OMRON.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- E5EC-CC2ASM-013 OMRON.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0 E5EC-CC2ASM-013 OMRON. 5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the TTemperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5EC-CC2ASM-013.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs OMRON E5EC-CC2ASM-013.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.