Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Resistance thermometer input, --.
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
clamp terminal blocks.
manual, RUN/STOP, and alarms) and the PV or SV.
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 20cm.
Lead wire type: Heat resistive .
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON E5GN-Q103LD-FLK.
Ideal for the thermal input devices of Temperature Controllers
E5GN-Q103LD-FLK
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Classification: Exclusive Models.
Description: Waterproof model.
Temperature range (See note 3.): -50°C to 180°C OMRON E5GN-Q103LD-FLK.
Element type: Pt100.
Conductor type: 3-conductor system.
Class: B.
Protective tubing material: Fluororesin tubing.
Terminal type: Exposed lead wires.
Page: 24.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers OMRON E5GN-Q103LD-FLK.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Control output: Linear current output *1.
Auxiliary output: Two.
Communications: RS-485.
Heater burnot: Detection for Single-phase heater.
Event inputs: --.
Power supply voltage: 24 VAC/VDC.
The E5DC-800 Mounts to DIN Track and Is Ideal,
for Connections to HMIs and PLCs.
It provides the Same Easy Operation and,
Advanced Performance as the Rest of the,
E5@C-800 Series.
A slim body at 85 × 22.5 mm (D × W) that fits into narrow control,
panels and mounts to DIN Track.
Removable terminal block for easy replacement to simplify maintenaance E5GN-Q103LD-FLK.
High-speed sampling at 50 ms for applications with high-speed,
temperature increases.
Easy connections to a PLC with programless communications.
Models are available with up to 2 auxiliary outputs and 1 event input to,
commplete basic functions E5GN-Q103LD-FLK.
A white PV display (height: 8.5 mm) is easy to read when setting up,
checking alarms, and making settings in a control panel.