Name: HFU with DeviceNet Communications *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, None.
Communications functions: DeviceNet communications.
Input type: No input.
Terminal: Screw-less clamp.
Devices.
systems optimally suited to the application.
programming design.
requirements.
optimum cycle control for high-accuracy regulation with minimal noise.
Autotuning (AT) can be used for independent heating/cooling PID control.
response method.
Communications Unit.
With the help of microcomputer can achieve high precision (with 0.1 degrees C as the unit) of the temperature control.
Combined use of control equipment, adjustable sensitivity.
Attached to facilitate the energy saving operation of the set value conversion function, as well as ease of operation to stop the control function OMRON EJ1N-HFUB-DRT. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6
EJ1N-HFUB-DRT4 dia. .
Protective tubing length L: 35cm.
Lead wire type: Heat resistive.
Lead wire length M : 8m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers OMRON EJ1N-HFUB-DRT.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling OMRON EJ1N-HFUB-DRT.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the staate of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV EJ1N-HFUB-DRT.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output EJ1N-HFUB-DRT.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.