If can use: closed loop vector control; spindle positioning, position control, speed control, servo lock zero.
Suitable frequency converter: FR-A700.
Power: 15kw.
Voltage: 200V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost MITSUBISHI FR-A7AP.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving
FR-A7AP The frequency of a transducer can be set by a digital signal from an external BCD or binary code.
BCD code 3 (maximum 999).
BCD code 4 (maximum 9999).
Binary code 12 (max FFFH).
Binary code 16 (max FFFFH). MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V MITSUBISHI FR-A7AP.
Frequency converter capacity: 2.2KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used MITSUBISHI FR-A7AP. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced FR-A7AP MITSUBISHI.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft FR-A7AP MITSUBISHI. MITSUBISHI inverter FR-E720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 0.4KW.
In order to ensure the reliability of production, all production machinery in the design of power with drive, there is a certain amount of surplus.
When the motor can not run under full load, in addition to meet the requirements of power driven,
The surplus torque increases the active power consumption, resulting in the waste of electric energy FR-A7AP MITSUBISHI.
Speed control method of fan and pump eequipment traditional by regulating the entrance or exit of the baffle, valve opening to regulate air flow and water flow
, the input power is large, and a large amount of energy consumption in the baffle, the valve in the processs of closure MITSUBISHI FR-A7AP FR-A7AP.
When using variable frequency control, if the flow rate is reduced, the speed of the pump or fan can be reduced to meet the requirements.