Specifications: Inputs, NPN (+ common), 8 points.
I/O connections: Sensor I/O connector.
Supplied from the communications. connector.
Rated I/O power supply voltage: 24 VDC.
Remote I/O Terminals with High.
Degree of Environmental Resistance.
(IP67) in Product Lineup Including.
Economical Input, Output, and Mixed I/O Models.
operation status monitoring and effective maintenance.
construction. (IP67)
connection with hydraulic valve devices.
EtherCAT-compatible encoder input terminal which,
enables high-speed and accurate control.
Two counter function available.
Pulse count within 32 bit range.
Maximum input pulse frequency of 4MHz,
(Line driver input after quadrature).
High-speed network EtherCAT enables,
high-speed and accurate control OMRON DRT2-ID08CL.
Selectable two input types:
Open collector input and line driver input
DRT2-ID08CL
Built-in two external latch inputs,
and one reset input.
Selectable node address settings: setting with,
rotary switches and setting on tool software.
Detachable screw terminal will facilitate,
the maintenance work. Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection OMRON DRT2-ID08CL.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site OMRON DRT2-ID08CL.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Input capacity: 32 points.
Internal I/O common: NPN DRT2-ID08CL OMRON.
ON voltage: 15 VDC min. (between each in,
put terminal and the V terminal).
OFF voltage: 5 VDC max. (between each in,
put terminal and the V terminal).
OFF current: 1 DRT2-ID08CL OMRON. 0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms,
1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms.
(Default setting: 1ms)
Number of circuits per common: 32 points/common DRT2-ID08CL OMRON.
Input indicators: LED display (yellow).
Isolation method: No isolation.
I/O power supply method: Supplied from unit power supply.
Input device supply current: 50 mA/point.
Unit power supply current consumption: 230 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 220 g max.
Expansion functions: No.
Short-circuit protection function: Available.
(Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminaal is provided for,
each connector DRT2-ID08CL.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
sswitch and with tool software OMRON DRT2-ID08CL.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.