Number of beams: 8.
Protective height: 185mm.
Model: NPN output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions.
Number of beams: 76.
Protective height: 1550mm.
New Standard of Safety Light.
Curtain,Offering Both Robustness.
and Reliability.
Robust and compact.
New muting function to increase both productivity and safety.
All models designed for global use. PNP/NPN selection by.
DIP switch.
Conforming to major international standards including OMRON F3SJ-B0185N25.
Chinese standard GB 4584. Actuator: Plunger
F3SJ-B0185N25
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement OMRON F3SJ-B0185N25.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Roller plunger.
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC/1NO (Slow-action) OMRON F3SJ-B0185N25.
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Easy programming for complex safety control.
Stand-alone Safety Controller for small and mid-sized machinery.
Three types of CPU with different I/O size to suit the application.
Four types of Expansion I//O Units for hard-wired diagnosis or standard signals F3SJ-B0185N25.
Clear diagnosis and monitoring via Ethernet or Serial connection.
Various kinds of safety devices directly connectable like noncontact,
switches and safety mats.
Easy design, vverification, standardization and reusage of,
safety control by unique programming software F3SJ-B0185N25.
ISO 13849-1 (PLe/Category 4), IEC61508 (SIL3) certified.