Convert connector to screw relay terminal.
2 wire connection, no need to use common terminal.
Negative common end use.
Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Can be used to locate the wiring between drives.
Trunk terminal available for external input signal. "Universal output function: leakage type.
Program capacity: 20K step.
Basic operations processing speed: 40ns.
Communication interface: USB/Ethernet MITSUBISHI FA-TB32XYP3.
Control mode: stored procedure repeated operation.
Input / output points: 1024 points
FA-TB32XYP3
End cap.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement MITSUBISHI FA-TB32XYP3.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ".
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s MITSUBISHI FA-TB32XYP3.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators. "Convert connector to screw relay terminal FA-TB32XYP3 MITSUBISHI.
The action of the signal of the conversion module is shown in the light of the lamp.
Positive common end display FA-TB32XYP3 MITSUBISHI. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Differential output.
Axis of control: 4.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis FA-TB32XYP3 MITSUBISHI.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start.
The use of steps in accordance with the auxiliary function can be.
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH, bit 88CH data can be displayed in real time FA-TB32XYP3.
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check.
Can only choose the necessary items from the rich monitoring information and monitor the display MITSUBISHI FA-TB32XYP3.
Through the test function, do not have to control procedures can also be implemented to confirm the basic action.