LK166
Home >> Products >> MITSUBISHI >> Inverter >> Inverter accessories >> FR-ABR-H0.75K High frequency braking resistor MITSUBISHI FR-ABR-H0.75K

FR-ABR-H0.75K High frequency braking resistor MITSUBISHI FR-ABR-H0.75K

Brand: MITSUBISHI
Name: High frequency braking resistor
Model: FR-ABR-H0.75K
Power: 0.75kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor.
The installation of thermal relay, to avoid overheating and burn the braking resistor.

MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 55kw.
SLD converter rated current: 316A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
PID target value can be set directly from the operator panel. Flexible change settings.
In the 1 inverter, through the PID control of parallel connection pump (up to 4 units) can adjust the amount of water and so on MITSUBISHI FR-ABR-H0 FR-ABR-H0.75K75K.
1 pumps driven by parallel connection of the pump machine, in addition to the pump for power frequency drive.
The number of power frequency driven pump, according to the automatic adjustment of water.
The liquid crystal panel options (FR-LU08) can be converted to a more intuitive display unit% units MITSUBISHI FR-ABR-H0.75K.
Through the use of wind, temperature and other familiar units can be simple to maintain and adjust the display. Applicable motor capacity: 2.2KW.
Rated current: 1.2A.
Power supply voltage: three phase 400V.
Frequency converter and GOT supporting the use, to achieve a higher price.
SIMPLE GOT series can be directly connected to the IS70 series inverter.
GOT can be directly connected with the inverter MITSUBISHI FR-ABR-H0.75K. After connecting the two, the communication parameters can be automatically set.
In addition, the software can display the soft component of the control function in the GOT, even when the multi frequency converter is connected,
Can also be unified management with 1 GOT FR-ABR-H0.75K MITSUBISHI.
Through the GOT screen to create software to import the picture data after the GOT,
Only use RS-422 connection GOT and frequency converter,
Can change the inverter speed / direction, monitoring the output frequency / output current and set a variety of parameters FR-ABR-H0.75K MITSUBISHI. "MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 280KW.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way FR-ABR-H0.75K MITSUBISHI.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainlly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FR-ABR-H0.75K.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter MITSUBISHI FR-ABR-H0.75K. "


...More relevant models >>>>